Void forming tubes

Applications:

Economical and easy application

Displacement pipes allow for the safe, quick and economical construction of hollow bodies in hollow plate bridges and ceilings. The dimensional accuracy, tightness and high resistance to deformation of these industrial cavity elements guarantee the implementation of the calculated static values in the structure.

Your Advantage:

  • Greatest available dia. 1,500mm
  • Delivered in every transportable length
  • Additional shearing connection with the concrete by means of their corrugated profile
  • The implemented reduction of the Tube end avoid undesired notch tensions
round

Pipe Type 7631.01

Hydra Void forming Tubes allow for the safe, quick and economical construction of hollow bodies in hollow plate bridges and ceilings.

round
round

Material

Bright steel

galvanized steel

Delivery

As single Tube max. length 6,00 m

Overlength on demand

length tolerance ± 50 mm

DNInside-/ Outside dimensionsProfil heightWeight
d1 in mmd3d2Toleranceshpkg/m
400384405± 2,58,04,56
450434455± 2,58,05,59
500484505± 2,58,06,22
550534555± 2,58,06,95
600584605± 2,58,07,48
650634655± 2,58,08,12
700685706± 2,58,010,99
750735756± 2,58,011,78
800785806± 2,58,012,58
850835856± 2,58,013,37
900885906± 2,58,014,17
950935956± 2,58,019,10
10009851006± 2,58,020,10
105010351056± 3,58,022,30
110010861108± 3,58,024,36
115011341158± 3,58,025,48
120011861208± 3,58,026,59
125012341258± 3,58,027,71
135013341358± 4,08,030,00
150014861508± 4,08,034,10

Building Shell Pipes

Efficient, cost-saving and resource-preserving building: The use of building shell pipes will help you save weight and material, also through low ceiling thicknesses. The load-bearing capacity will nevertheless be preserved, higher span widths are possible. Ideal for application in the construction of modern, slender buildings.

round

Your Advantage:

  • weight reducing
  • saving of material
  • bearing capacity
  • conservation of resources

Material

Surface bright – cold-rolled strip ST 2 EN 10139

thickness tolerance EN 10140

Surface galvanized – cold-rolled ST 02 Z

Delivery

As individual Tube in maximun delvery lenghts of 6,00 m. Greater lengths upon request. Permissible length tolerance +/- 50 mm

DNInside-/ Outside dimensionsProfil heightWeight
d1d2Toleranceshpkg/m ± 10%
200200208± 1,03,81,70
250250260± 2,04,82,24
290290300± 2,04,82,50
300300310± 2,04,82,68
310310320± 2,04,82,80
350350360± 2,04,83,11
400400410± 2,04,83,55